Takardar bayanai | MID 6KTL3-XL | MID 8KTL3-XL | MID 10KTL3-XL | Saukewa: MID11KTL3-XL | Saukewa: MID12KTL3-XL |
Bayanan shigarwa | |||||
Max.DC iko | 65000W | 10400W | 13000W | 13000W | 15600W |
Max.DC irin ƙarfin lantarki | 800V | ||||
Wutar lantarki ta farko | 250V | ||||
MPPT irin ƙarfin lantarki | 160-800V | ||||
Wutar lantarki mara kyau | 360V | ||||
Max. shigar da halin yanzu a kowane MPPT | 25 A | ||||
Fitowa (AC) | |||||
Ƙarfin fitarwa AC mai ƙima | 6000W | 8000W | 10000W | 11000W | 12000W |
Max. AC bayyanannen iko | Farashin 6600VA | Farashin 8800VA | Farashin 11100VA | Farashin 12100VA | Farashin 13300VA |
Max. fitarwa halin yanzu | 16.5A | 22.1 A | 27.8 A | 30.3A | 30.3A |
Wutar lantarki na AC | 133V/230V | ||||
Mitar grid AC | 50Hz/60Hz | ||||
Max. inganci | 98.8% |
Takardar bayanai | MIN 7000TL-X(E) | MIN 8000TL-X(E) | MIN 9000TL-X | MIN 10000TL-X |
Bayanan shigarwa | ||||
Max.DC iko | 12000W | 12000W | 13500W | 15000W |
Max.DC irin ƙarfin lantarki | 600V | |||
Fara wutar lantarki | 100V | |||
MPPT irin ƙarfin lantarki | 60-550V | |||
Wutar lantarki mara kyau | 360V | |||
Max. shigar da halin yanzu a kowane MPPT | 13.5A/27A | |||
Fitowa (AC) | ||||
Ƙarfin fitarwa AC mai ƙima | 7000W | 8000W | 9000W | 10000W |
Max. AC bayyanannen iko | 7000VA | 8000VA | Farashin 9000VA | 10000VA |
Max. fitarwa halin yanzu | 33.5 A | 33.5 A | 43A | 45.5A |
Ƙarfin wutar lantarki na AC (kewayon*) | Tsoffin: 240V tsaga-lokaci, na zaɓi: 208V & 240V lokaci ɗaya, 183-228@208V 211-264V@240V | |||
Mitar grid AC (kewaye*) | 50/60 Hz (45-55Hz/55-65 Hz) | |||
Max. inganci | 98.1% |
Takardar bayanai | Saukewa: MAC15KTL3-XL | Saukewa: MAC20KTL3-XL | Saukewa: MAC22KTL3-XL | Saukewa: MAC25KTL3-XL | Saukewa: MAC30KTL3-XL | Saukewa: MAC36KTL3-XL |
Bayanan shigarwa | ||||||
Max. shawarar ikon PV (don module STC) | 22500W | 30000W | 33000W | 37500W | 45000W | 54000W |
Max.DC irin ƙarfin lantarki | 1100V | |||||
Wutar lantarki ta farko | 250V | |||||
MPPT irin ƙarfin lantarki | 200V-1000V | |||||
Wutar lantarki mara kyau | 360V | |||||
Max. shigar da halin yanzu a kowane MPPT | 52A/52A/52A | |||||
Fitowa (AC) | ||||||
Ƙarfin fitarwa AC mai ƙima | 15000W | 20000W | 22000W | 25000W | 30000W | 36000W |
Max. AC bayyanannen iko | 16600VA@220VAC | 22200VA@220VAC | 24400VA@220VAC | 27800VA@220VAC | 33300VA@220VAC | 36000VA@220VAC 39200VA@240VAC |
Max. fitarwa halin yanzu | 43.6 A | 58.3 A | 64.0 A | 73.0 A | 87.4A | 94.5A |
Ƙarfin wutar lantarki na AC (kewayon*) | 127V/220V (101.6-139.7V) | |||||
Mitar grid AC (kewaye*) | 50/60 Hz (46 ~ 54/56 ~ 64Hz) | |||||
Max. inganci | 98.8% |
Hoja de datos | Saukewa: MAX50KTL3-XL2 | Saukewa: MAX60KTL3-XL2 | Saukewa: MAX70KTL3-XL2 | Saukewa: MAX75KTL3-XL2 |
Datos de entrada (CD) | ||||
Max.DC iko | 100000W | 120000W | 105000W | 112500W |
Rango de potencia maxima* | 370-650V | |||
Voltaje de arranque | 195V | |||
Voltaje mai suna | 550V | |||
Rango de voltaje de MPPT | Saukewa: 180V-850VDC | |||
Maxima corriente na MPPT | 40A | |||
Salida (CA) | ||||
Potencia nominal CA | 50000W | 60000W | 70000W | 75000W |
Potencia aparente maxima | Farashin 55500VA | Farashin 66600VA | 66000VA @ 208V 70000VA @ 220V 73000VA @ 230V | 71000VA @ 208V 75000VA @ 220V 78400VA @ 230V |
Voltaje mai suna CA (Rango*) | 127V/220V (101.6-139.7V) | |||
Voltaje mai suna CA (Rango*) | 127V/220V (101.6-139.7V) | |||
Frecuencia de red CA (Rango*) | 50/60Hz (45 ~ 55Hz/55-65 Hz) | |||
Maxima ficiencia | 98.8% |
Takardar bayanai | Saukewa: MAX50KTL3 | Saukewa: MAX60KTL3 | Saukewa: MAX70KTL3 | Saukewa: MAX80KTL3 |
Bayanan shigarwa | ||||
Max.DC iko | 65000W | 78000W | 91000W | 104000W |
Max.DC irin ƙarfin lantarki | 1100V | 1100V | 1100V | 1100V |
Fara wutar lantarki | 250V | |||
MPPT irin ƙarfin lantarki | 200V-1000V | |||
Wutar lantarki mara kyau | 585V | 585V | 600V | 600V |
Max. shigar da halin yanzu a kowane MPPT | 25 A | |||
Fitowa (AC) | ||||
Ƙarfin fitarwa AC mai ƙima | 50000W | 60000W | 70000W | 80000W |
Max. AC bayyanannen iko | Farashin 55500VA | Farashin 66600VA | Farashin 77700VA | Farashin 88800 |
Max. fitarwa halin yanzu | 80.5A | 96.6 A | 112.7A | 128.8 A |
Wutar lantarki na AC | 230V/400V | |||
Mitar grid AC | 50Hz/60Hz | |||
Max. inganci | 98.8% | 98.8% | 99.9% | 99.9% |